Monoflanges combine the event as high as three valves in an especially compact body, because of a precise network of internal passages and valve chambers. But what really happens in the monoflange valve, once installed?
In a chemical process a high response speed is necessary for some control applications. Among the variables that affect the response time may be the volume and the length between process and instruments. If the medium to be measured is gas, and the procedure will fluctuate strongly at times or if the control is crucial, mounting the instrument close to the process is the solution.
Vibrations are also critical, for example, if impulse lines are connected to a vessel. The longer the hook-up, the wider may be the amplitude of the vibration causing possible failures of the nozzle. Definitive includes one, two or three needle valves in the compact, flange-shaped body, allowing a substantial reduction in volume, dimensions, weight and potential leakage points.
Know It All may be the solution
With respect to the requirements of the plant it really is installed in, the monoflange can incorporate one, several valves. In a monoflange with two valves (block & bleed), one valve (with a blue cap) isolates the process and the other (with a red cap) regulates the venting of the medium trapped inside the instrument. That is mostly found in applications which are relatively uncritical (e.g. low pressure) or where a first shut-off valve is provided right before the monoflange.
The safest configuration, and the main one we advise for aggressive media or critical operating conditions, may be the three-valve monoflange or the so-called double block & bleed (DBB), which features two shut-off valves in series and something valve for venting.
Monoflange functionality
The monoflange bodies are drilled internally with holes which connect the annular valve chambers.
The following picture illustrates the procedure inside a DBB monoflange:
The flow enters the monoflange from the pipeline and stops below the initial shut-off valve [1];
When the first shut-off valve [1] opens, the flow proceeds towards the next shut-off valve [2] ; when the valve [2] is open, the instrument is thus connected to the process line;
When the first shut-off valve [1] is closed, the medium trapped between valve and instrument can be discharged via the vent valve [3] through the vent outlet. Both shut-off valves [1, 2] are in an angled position, that allows the flow to feed them.
The two shut-off valves allow an improved isolation from the procedure: In case the initial shut-off valve does not isolate the medium properly, the second one will act as a safety means against accidental leaks. Occasionally, customer specifications do not allow the medium to stay touch with the instrument when it’s not measuring. For this reason the medium will be discharged utilizing the vent line. In other cases ? because of the vent line ? instruments can be easily calibrated without dismounting them from the line.