The importance of supervised monitoring modules utilized in control and monitoring of extinguishing techniques

In many locations from chemistry laboratories to industrial amenities, so as to guarantee the security of life and property against a possible fire hazard, extinguishing systems are used along with detection and alarm techniques. It is also extremely essential that the extinguishing techniques put in could be triggered by the hearth extinguishing control panel, in order to eliminate a possible fire with early intervention.
In order to fulfill these wants, and with 35 years of sectoral information and expertise, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel operating in accordance with the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be started manually and remotely; and
to guarantee that the extinguishing process may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
เกจวัดความดันแก๊ส are produced using surface-mount technology and are aimed at making the automation of the extinguishing system and fire and gasoline detection system good.
Image copyright: Mavili
Mavili Elektronik develops its products by always contemplating the needs of the set up. In cases that require the combination of the extinguishing system with the clever addressable fire detection system, it supplies options via the monitoring modules that also have a ‘supervised’ choice.
Supervised monitoring pressure gauge digital ราคา play an important function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a potential open or quick circuit within the wiring between the contact monitoring modules and the peripheral systems can cause disruption of the triggering, with probably critical consequences. For this reason, when selecting monitoring modules, it ought to be taken under consideration that they have supervised features.
Image copyright: Mavili
Since Maxlogic intelligent addressable fireplace detection and alarm control panels are continuously communicating with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to monitor conditions similar to open circuits and quick circuits that may occur within the system. Many tasks could be performed within the hearth extinguishing installation, such because the management and monitoring of all valves that can interrupt the move of water, water flow alarm switches, pressure switch, and electrical or diesel fire pumps.
By including two contact monitoring modules to 2 separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be utilized to regulate errors and the opposite to regulate the hearth state of affairs, monitoring and control of the extinguishing system via an clever addressable fire detection and alarm system may be performed effectively.
For more information, go to www.mavili.com.tr/en